#!/bin/perl #+ # nspeclog -- generate logsheet data from image headers # # Purpose: # Given a list of images, parse the image headers and print # out a formatted list of data. With no arguments, parse all of # the images in the current directory. # # Usage: # nspeclog [n | images] # # Arguments: # n = number of latest images to parse. # images = names of images to parse. If no images are listed, # then all images in the current directory will be read # (EXCEPT for backup.fits). # # Output: # to STDOUT # # Restrictions # None # # Note: # The output from this program is extra wide. To print it, use # this command: # enscript -1r -c -f Courier9 -P lw4s # # You may need to alter the first line of this script for your # local perl install. # 1) Type "which perl" # 2) If the result is different than above, edit the first line # Note that the "#!" is needed before your path # # Exit values: # 0 = normal completion # 1 = wrong number of arguments # # Example: # 1) Generate log data for all images in the current directory: # nspeclog # # 2) Generate log data for the last 5 images in the current directory: # nspeclog 5 # # 3) Generate log data for all images in the directory # /s/sdata602/nirspec/2003jan01/spec: # nspeclog /s/sdata602/nirspec/2003jan01/spec/*.fits #- # Modification history: # 2002-Dec-30 GDW Original version (deeplog) # 2003-Aug-27 GDW Changed TTIME to EXPTIME # 2004-Oct-10 GDW Added "last n images" option # 2004-Nov-09 jlyke Adapted for NIRSPEC use (nspeclog) #----------------------------------------------------------------------- use Getopt::Std; use File::Basename; # get command-line options... getopts("h"); # define the name of this program... my( $base) = basename($0); # define usage my( $usage) = <=0 ; $i--){ if( ($images[$i] =~ m/backup.fits/) or # remove backup files ($images[$i] =~ m/^cam/) or # remove cam files not ($images[$i] =~ m/.fits$/ or $images[$i] =~ m/.fits.gz$/)){ splice( @images, $i, 1) } } # parse args... if ( @ARGV == 1 and $ARGV[0] =~ /^\d+$/ ) { $m = $ARGV[0]; if ( $m > @images ) { $m = scalar(@images) }; $m = -$m; @images = @images[ $m .. -1 ]; # extract last $m elements of image list } elsif ( @ARGV > 0 ) { @images = @ARGV; } # verify number of images... die "ERROR: No images found\n" unless @images; # get some information from the first NIRSPEC image... #for( $i=0 ; $i < @images ; $i++){ # %HeadValue = &GetFitsHead( $images[$i]); # last if (defined($HeadValue{'CURRINST'}) # and $HeadValue{'CURRINST'} =~ m/^NIRSP/) #} #die "ERROR: No NIRSPEC images found\n" # unless $HeadValue{'CURRINST'} =~ m/^NIRSP/; # print header... printf "\n"; printf "%-72s", "Project:"; printf "UT Date: %s", &BlankIfUndef($HeadValue{"DATE-OBS"}); printf "\n"; printf "%-72s", "Observers: " . &BlankIfUndef($HeadValue{"OBSERVER"}); printf "Weather:"; printf "\n"; printf "%-72s", "Data directory: " . &BlankIfUndef($HeadValue{"OUTDIR"}); printf "Seeing:"; printf "\n"; printf "\n"; $line = ''; for ( $i=0 ; $i<@X::keyword ; $i++ ) { $X::format[$i] =~ m/^%-?(\d+)/; $n = $1; $X::format[$i] =~ m/(\s+)$/; $space = $1; $buf = sprintf "%-${n}s$space", $X::title[$i]; print $buf; $buf =~ s/./_/g; $line .= $buf; } printf "\n"; printf "$line\n"; # loop over images... for ( $j=0 ; $j<@images ; $j++ ) { # read image header... %HeadValue = &GetFitsHead( $images[$j]); # skip non-NIRSPEC images... #next unless (defined($HeadValue{'CURRINST'}) # and $HeadValue{'CURRINST'} =~ m/^NIRSP/); # build filename field... $HeadValue{'FILENAME'} = (fileparse( $images[$j], '\..*'))[0]; # print results... for ( $i=0 ; $i<@X::keyword ; $i++ ) { if ( defined $HeadValue{$X::keyword[$i]} and $HeadValue{$X::keyword[$i]} ne $null ){ $HeadValue{$X::keyword[$i]} =~ s/^\s+//; # remove leading whitespace $HeadValue{$X::keyword[$i]} =~ s/\s+$//; # remove trailing whitespace printf $X::format[$i], $HeadValue{$X::keyword[$i]} } else { $X::format[$i] =~ m/^%-?(\d+)/; $n = $1; if ( not defined $HeadValue{$X::keyword[$i]}){ $buf = '?' } else { $buf = '' } printf "%-${n}s ", $buf; } } printf "\n"; } #----------------------------------------------------------------------- sub GetFitsHead { #----------------------------------------------------------------------- # get file name to read header from my $infile = shift; my( $excess, $comment); # reset output hashes to null my %HeadValue = (); my %HeadComment = (); # open the file with a shared lock to prevent it being modified # during reading... open TEST, "<$infile"; flock TEST, 1; # open input file using appropriate method... if ($infile =~ /\.gz$/i) { open INFITS, "gunzip --stdout $infile |"; $| = 1; # enable autoflush on gunzip output } else { open INFITS, $infile; } # initialize input variable to allow for end-of-header trapping $headline = " "; # loop thru FITS file 80 bytes at a time until end-of-header mark found until (substr($headline,0,3) eq "END") { read INFITS, $headline, 80 or die "unexpected end of file on read"; chomp($headline); # identify keyword name from first 8 bytes $name = substr($headline, 0, 8); $rest = substr($headline,9); # strip extra spaces off of keyword names $name =~ s/\s//g; # test if value is a string, handle single quotes if it is if (substr($rest,0,2) eq " '") { $lastquote = index($rest, "'", 2); $value = substr($rest,2,$lastquote-2); ($excess, $comment) = split (/\//, substr($rest, $lastquote)); } else { # otherwise split value from comment using / separator ($value, $comment) = split (/\//, $rest); $value =~ s/\s//g; } # add next value and comment to respective hashes unless ($name eq "END" or $name eq "") { $HeadValue{$name} = $value; $HeadComment{$name} = $comment; } } # close input FITS file close INFITS; close TEST; return %HeadValue; } #----------------------------------------------------------------------- sub AddColumn { #----------------------------------------------------------------------- my( $keyword, $title, $format) = @_; push( @X::keyword, $keyword); push( @X::title, $title); push( @X::format, $format); } #----------------------------------------------------------------------- sub BlankIfUndef { #----------------------------------------------------------------------- my( $value) = @_; if( defined $value){ return $value } else { return '' } }