There are now new and simpler scripts for diagnosing and fixing the most common grating move failures. First, log on to the motor controller VME crate. For observers, this is accessible from the pull-down "Engineering" menu (but you need to know the crate login name and password), or by connecting directly through the TIP line:
punaluu{lris1}: telnet tserver4 3009
Then, check the status of the grating turret and tilt mechanisms:
-> check_turretThe check_turret script reports the status of the grating turret position, the turret detent, the grating brake, and the grating tilt.
If the the problem seems to be in the turret or the detent, then home the turret:
-> home_gturretThis command home_gturret will home the grating tilt to a safe position before attempting to home the turret, so it IS safe to give this command even if the grating is not at home. This is a major improvement over the home_compound 0 command described below.
If the the problem seems to be in the grating tilt or brake, then try to home the grating:
-> home_grating
Here are some examples of the output of these new commands.
-> check_turret
Grating turret switch position : 0
API I1+I2 input bits reading: 0000011111111100
API turret bits reading : 0000
Grating turret user position: 4
Grating 1 is in the optical port.
Grating turret detent position : -1
API I1+I2 input bits reading : 1111111111111110
API detent limit-switch bits reading: 10
Detent is IN.
Grating brake switch position : -1
API I1+I2 input bits reading :
1111111111111110
API grating-brake limit-switch bits reading: 10
Grating brake is CLAMPED.
Grating tilt encoder reading: 11946
API I1 input bits reading: 01111011
Grating 1 is not at home.
Grating-turret subsystem check done.
value = 0 = 0x0
-> home_gturret Checking grating tilt ... ST:Time=62039000:mcs_limit(): Motor controller input2=11111110 ST:Time=62039690:mcs_limit(): Motor controller input2=11111101 ST:Time=62039930:mcs_limit(): Motor controller input2=10011100 ST:Time=62039930:File: lrs_mcs.c, Func:mcs_limit, Line: 382: ST:Time=62039930:Motor home bit is set. ST:Time=62040260:mcs_limit(): Motor controller input2=11111101 ST:Time=62040950:mcs_limit(): Motor controller input2=11111110 Homing grating turret ... ST:Time=62041460:mcs_limit(): Motor controller input2=11111110 ST:Time=62042030:mcs_limit(): Motor controller input2=11111101 ST:Time=62042300:mcs_limit(): Motor controller input2=11111100 ST:Time=62042300:File: lrs_mcs.c, Func:mcs_limit, Line: 382: ST:Time=62042300:Motor home bit is set. ST:Time=62043800:mcs_limit(): Motor controller input2=11111110 ST:Time=62044070:get_stage_pos_code(): returning 3 ST:Time=62044310:mcs_limit(): Motor controller input2=11111101 ST:Time=62044730:mcs_limit(): Motor controller input2=11111110 value = 0 = 0x0
-> home_grating ST:Time=62032656:mcs_limit(): Motor controller input2=11111110 ST:Time=62033346:mcs_limit(): Motor controller input2=11111101 ST:Time=62033586:mcs_limit(): Motor controller input2=10011100 ST:Time=62033586:File: lrs_mcs.c, Func:mcs_limit, Line: 382: ST:Time=62033586:Motor home bit is set. ST:Time=62033916:mcs_limit(): Motor controller input2=11111101 ST:Time=62034606:mcs_limit(): Motor controller input2=11111110 value = 0 = 0x0
Following is a description of troubleshooting procedures should a grating move repeatedly fail. This text below describes how to diagnose and fix turret problems using other VME crate commands. These commands may help diagnose and fix problems in case the simpler commands above fail.
First, log on to the motor controller VME crate. This is accessible from the LRIS Tools menu (the Engineering pull-down menu for observers), or by connecting directly through the TIP line:
punaluu{lris1}: telnet tserver4 3009
Grating turret moves are completed in the following sequence (with corresponding VME macro command available to the troubleshooter):
The VME output is comprised of a series of reads through the API motor controllers:
ST:Time=60810830:Set grating position = 951207 W0:Time=60811010:All gratings home bits not set! Homing grating tilt. ST:Time=60811190:mcs_limit(): Motor controller input2=11111110 ST:Time=60811910:mcs_limit(): Motor controller input2=11111101 ST:Time=60812600:mcs_limit(): Motor controller input2=10011100 ST:Time=60812600:File: lrs_mcs.c, Func:mcs_limit, Line: 381: ST:Time=60812600:Motor home bit is set. ST:Time=60812810:mcs_limit(): Motor controller input2=11111101 ST:Time=60813530:mcs_limit(): Motor controller input2=11111110 ST:Time=60813833:move_compound(): First move started ST:Time=60814073:mcs_limit(): Motor controller input2=11111110 ST:Time=60814763:mcs_limit(): Motor controller input2=11111101 ST:Time=60814853:move_compound(): First move done ST:Time=60814853:move_compound(): main move started ST:Time=60816201:move_compound(): main move done ST:Time=60816201:move_compound(): Last move started ST:Time=60816441:mcs_limit(): Motor controller input2=11111101 ST:Time=60816981:mcs_limit(): Motor controller input2=11111110 ST:Time=60817071:move_compound(): Last move doneWhen the observer selects his grating (wavelength) setting, 3 more moves occur:
-> show_current
Stage Current Position
----- ----------------
0. grating_turret 2
1. grating_turret_detent -1
2. grating_brake -1
3. grating_tilt 19139
4. red_filter_selector 548051
5. red_filter_changer 1860115
6. blue_filter_selector -2
7. blue_filter_changer -1
8. red_camera_focus 4101789
9. slitmask_selector 3331181
10. slitmask_changer 1761157
11. offset_guider_focus 1885379
12. offset_guider_pos 4546864
13. offset_guider_filter 0
14. slitview_guider_filter 3
15. trapdoor -1
16. polar_calibration -2
17. polar_waveplate 6
value = 0 = 0x0
Note the stage numbers and identifications. For stages 0-3, valid positions
are:
| Number | Stage drive | Valid positions | Error position |
|---|---|---|---|
| 0 | grating_turret | optical(2,4,6,8,10), service(1,3,5,7,9) | -2 |
| 1 | grating_turret_detent | -1(in),1(out) | 2 |
| 2 | grating_brake | -1(in),1(out) | 2 |
| 3 | grating_tilt | 0(home)-100000 |
The stage positions must be individually read at low level before proceeding. To check the positions of individual stages, use the show command, as in:
-> show 0 -> show 0 Stage = 0. Position = 3 value = 0 = 0x0 -> ST:Time=126692:get_stage_pos_code(): returning 1 -> -> show 1 ST:Time=173816:Motor controller input2=11111110 Stage = 1. Position = -1 value = 0 = 0x0 -> -> show 2 ST:Time=174116:Motor controller input2=11111110 Stage = 2. Position = -1 value = 0 = 0x0 -> -> show 3 Stage = 3. Position = 15 value = 0 = 0x0 ->
Also, all 4 of these stages must be in a valid position in order for XLRIS to broadcast a grating position; otherwise the position is broadcast UNKNOWN.
Note that the grating_tilt does not appear homed (Position = 15) in the above example. In order to check whether any gratings are NOT homed, the tilt stage must be addressed at the API level as follows:
-> api api>:0 0> api> set 1 api> ver i1 ; the word i1 should be read twice api> ver i1 0 "I1 = 10111011" If one of the gratings is not homed, one of the first 5 bits will be 0; in this example grating 2 is not homed.
-> clamp_grating_brakeIf it does not go to the IN (-1) limit, try to cycle it unclamped and clamped again:
-> unclamp_grating_brake
-> clamp_grating_brakeIf it makes it to the IN limit, and all other positions are valid, then you can continue with high-level grating moves via XLRIS.
-> home_gratingor
-> home_compound 3
-> move_detent_out
-> home_compound 0This will drive the turret to its home position (1), which will still be broadcast to XLRIS as UNKNOWN. After this move completes, show the value of the turret detent (show 1); if it is IN (-1) then you can continue with high-level grating moves via XLRIS.
-> move_detent_inIf it does not go to the IN (-1) limit, try to cycle it out and in again:
-> move_detent_out
-> move_detent_in
-> home_compound 3
There are: