The keywords listed below are relevant to the telescope drive and control system (DCS). They can be examined from an LRIS account on punaluu by typing:
show -s dcs keywordsIn general, these keywords cannot (and should not) be modified by the LRIS user.
| Keyword | Description | Datatype |
|---|---|---|
| ADCERRS | adc error string | string |
| ADCERVL | adc error status | integer number |
| ADCHALT | adc halt command | logical |
| ADCHALTC | adc halt command complement | logical |
| ADCINIT | adc initialization command | logical |
| ADCINITC | adc initialization command complement | logical |
| ADCNEED | adc needed | logical |
| ADCPRENA | ADC prism calc enable disable flag | enumm |
| ADCPRSEP | ADC prism seperation | double number |
| ADCSRVER | adc servo error | double number |
| ADCSTAT | adc state | enumm |
| ADCSTBY | adc standby command | logical |
| ADCSTBYC | system standby command complement | logical |
| ADCSTST | adc state string | string |
| AIRMASS | air mass | double number |
| AUTACK | guider cmdAck | integer number |
| AUTACTIV | guider active | logical |
| AUTANGL | guider to porg angle | double number |
| AUTAZAC | guider az accumulated err | double number |
| AUTAZBW | guider az posn loop bandwidth | double number |
| AUTAZER | guider az err | double number |
| AUTAZGN | guider az effective gain | double number |
| AUTAZGN0 | guider az nominal gain | double number |
| AUTBADST | guider badstat | logical |
| AUTCAPR | guider capture radius | double number |
| AUTCLEAR | guider clear acc corr | logical |
| AUTCYCLE | guider cycle | integer number |
| AUTELAC | guider el accumulated err | double number |
| AUTELBW | guider el posn loop bandwidth | double number |
| AUTELER | guider el err | double number |
| AUTELGN | guider el effective gain | double number |
| AUTELGN0 | guider el nominal gain | double number |
| AUTFLIP | guider to porg y flip | logical |
| AUTFWHM | guider fwhm | double number |
| AUTGO | guider go flag | string |
| AUTNOST | guider nostat | logical |
| AUTPAUSE | guider pause | integer number |
| AUTPER | guider period flag | double number |
| AUTPSEX | guider pauseX | double number |
| AUTPSEY | guider pauseY | double number |
| AUTREFX | guider X reference | double number |
| AUTREFY | guider Y reference | double number |
| AUTRESUM | guider resume | integer number |
| AUTRESX | guider resumeX | double number |
| AUTRESY | guider resumeY | double number |
| AUTSKY | guider sky counts | double number |
| AUTSQNUM | guider seqnum | integer number |
| AUTSTAR | guider star counts | double number |
| AUTSTOP | guider stop | integer number |
| AUTTIME | guider total time | double number |
| AUTTMSMP | guider time stamp | double number |
| AUTXCENT | guider Xcent | double number |
| AUTXFER | guider xfer cor to coll | logical |
| AUTYCENT | guider Ycent | double number |
| AUXBOOT | aux cage reboot | logical |
| AUXCPU | aux cpu usage | double number |
| AUXUP | aux cage up status | logical |
| AUXVERS | aux cage software version | string |
| AXEERRS | axes error string | string |
| AXEERVL | axes error status | integer number |
| AXEHALT | axes halt command | logical |
| AXEINIB | axes initialization command blocking | logical |
| AXEINIT | axes initialization command | logical |
| AXENEED | axes control needed | logical |
| AXESTAT | axes control status | enumm |
| AXESTBY | axes standby command | logical |
| AXESTOP | axes emergency stop command | logical |
| AXESTST | axes state string | string |
| AZ | telescope azimuth | double number |
| AZ1 | telescope azimuth | double number |
| AZ2 | telescope azimuth | double number |
| AZACCEL | telescope azimuth accel | double number |
| AZBANDW | az posn loop bandwidth | double number |
| AZBCODE | telescope azimuth barcode | double number |
| AZDEST | azimuth destination | double number |
| AZOFF | azimuth offset | double number |
| AZPE | azimuth servo posn error | double number |
| AZSRVER | azimuth servo error | double number |
| AZSRVMO | azimuth servo mode | integer number |
| AZVEL | telescope azimuth velocity | double number |
| CA | collimation azimuth | double number |
| CAINC | collimation azimuth increment | double number |
| CALOCAL | collimation azimuth local | double number |
| CASESS | collimation azimuth session | double number |
| CE | collimation elevation | double number |
| CEINC | collimation elevation increment | double number |
| CELOCAL | collimation elevation local | double number |
| CESESS | collimation elevation session | double number |
| CIEBOOT | cie cage reboot | logical |
| CIECPU | cie cpu usage | double number |
| CIEUP | cie cage up status | logical |
| CIEVERS | cie cage software version | string |
| COPRESET | collimation preset | enumm |
| CURRINST | current instrument | string |
| DATE | universal date | double number |
| DATE-OBS | universal date of observation | double number |
| DCSERRS | drive and control error string | string |
| DCSERVL | drive and control error status | integer number |
| DCSHALT | drive and control halt command | logical |
| DCSHOST | drive and control host | string |
| DCSINDON | drive and control initialization done | logical |
| DCSINIB | drive and control initialization command blocking | logical |
| DCSINIT | drive and control initialization command | logical |
| DCSLOCK | drive and control locked | logical |
| DCSSTAT | drive and control status | enumm |
| DCSSTBY | drive and control standby command | logical |
| DCSSTST | drive and control state string | string |
| DCSVERS | drive and control version | string |
| DDEC | diff decl rate | double number |
| DEC | telescope declination | double number |
| DECBASE | telescope declination base | double number |
| DECOFF | declination offset | double number |
| DIFFPTDW | difference betw pri mirr temp dewpoint | double number |
| DIFFSTDW | difference betw secondary temp dewpoint | double number |
| DOFFGE | diff tracking offset guide ena | integer number |
| DOMEDSEL | dome demand select | enum |
| DOMEERRS | dome error string | string |
| DOMEERVL | dome error status | integer number |
| DOMEHALT | dome halt command | logical |
| DOMEINIB | dome initialization command blocking | logical |
| DOMEINIT | dome initialization command | logical |
| DOMELITE | dome light control and status | enum |
| DOMENEED | dome needed | logical |
| DOMEPOSN | dome azimuth | double number |
| DOMESLEW | dome slew command | logical |
| DOMESTAT | dome status | enumm |
| DOMESTBY | dome standby command | logical |
| DOMESTST | dome state string | string |
| DOMHORND | dome horn disable command | logical |
| DOMHORNE | dome horn enable command | logical |
| DOMHORNS | dome horn sound command | logical |
| DRA | diff ra rate | double number |
| DSTART | diff rate start mjd | double number |
| DTFRAM | differential tracking frame | integer number |
| DTRACK | differential tracking enabled | logical |
| DTRESET | differential tracking reset | logical |
| DTRX | diff x rate | double number |
| DTRY | diff y rate | double number |
| EL | telescope elevation | double number |
| ELACCEL | telescope elevation accel | double number |
| ELBANDW | el posn loop bandwidth | double number |
| ELBCODE | telescope elevation barcode | double number |
| ELDEST | elevation destination | double number |
| ELOFF | elevation offset | double number |
| ELPDSTS | elevation physical destination slow | double number |
| ELPE | elevation servo posn error | double number |
| ELSRVER | elevation servo error | double number |
| ELSRVMO | elevation servo mode | integer number |
| ELVEL | telescope elevation velocity | double number |
| EQUINOX | telescope equinox | double number |
| ERRBAR | targ coord error bar | double number |
| ESTOPAAA | emergency stop status AAA | logical |
| ESTOPSAA | emergency stop status SAA | logical |
| EXPOSIP | instrument exposure in progress | logical |
| FLAMP3 | flat lamp control 3 | enum |
| FLAMP4 | flat lamp control 4 | enum |
| FLAMP5 | flat lamp control 5 | enum |
| FLAMP6 | flat lamp control 6 | enum |
| FLIMAGIN | flat lamp control 1 | enum |
| FLSPECTR | flat lamp control 2 | enum |
| FOCALLEN | telescope focal length | double number |
| FOCALSTN | focal station | enum |
| FOCALSTR | focal station string | string |
| FRAME | telescope frame | enumm |
| GOTOBASE | go to base | logical |
| GUIDING | guiding on | logical |
| GUIDWAVE | guidestar wavelength | double number |
| HA | telescope hour angle | double number |
| HALT | halt telescope | logical |
| INSTANGL | porg to instrument angle | double number |
| INSTFLIP | porg to instrument y flip | logical |
| INSTRUME | instrument name | string |
| INSTXOFF | instrument x offset | double number |
| INSTYOFF | instrument y offset | double number |
| LATITUDE | geodetic latitude | double number |
| LOGSET | loglevel set bit | integer number |
| LST | local apparent sidereal time | double number |
| MARK | mark current as base | logical |
| MARKCOLL | mark collimation | integer number |
| MJD | modified julian date | double number |
| MJD-OBS | modified julian date of observation | double number |
| MOV2SKY | pointing move to sky command | logical |
| MOV2SKYC | pointing move to sky command complement | logical |
| MOV2SKYE | pointing move to sky command error string | string |
| MOV2SKYS | pointing move to sky command error status | integer number |
| MOVEPEND | move pending | logical |
| MOVETEL | move telescope | enum |
| MOVETMOT | move pend timeout | integer number |
| NASCCWLM | nasmyth ccw limit | double number |
| NASCWLM | nasmyth cw limit | double number |
| NASELLM | nasmyth el limit | double number |
| NODSET | nod set | enumm |
| NODTEL | nod telescope | enumm |
| NODVIS | nod visible | logical |
| NOGROT | select non rotated guider | integer number |
| NRX | nasmyth rotator displacement x | double number |
| NRY | nasmyth rotator displacement y | double number |
| PARANG | parallactic angle astrometric | double number |
| PARANTEL | parallactic angle telescope | double number |
| PMNOSUP | proper mtn not supplied | logical |
| PNTERRS | pointing error string | string |
| PNTERVL | pointing error status | integer number |
| PNTHALT | pointing halt command | logical |
| PNTHALTC | pointing halt command complement | logical |
| PNTINIB | pointing initialization command blocking | logical |
| PNTINIT | pointing initialization command | logical |
| PNTINITC | pointing initialization command complement | logical |
| PNTNEED | pointing control needed | logical |
| PNTOFF | pointing offset command | logical |
| PNTOFFC | pointing offset command complement | logical |
| PNTOFFE | pointing offset command error string | string |
| PNTOFFS | pointing offset command error status | integer number |
| PNTSLEW | pointing slew command | logical |
| PNTSLEWC | pointing slew command complement | logical |
| PNTSLEWE | pointing slew command error string | string |
| PNTSLEWS | pointing slew command error status | integer number |
| PNTSNAP | snap pointing data | integer number |
| PNTSTAT | pointing control status | enumm |
| PNTSTBY | pointing standby command | logical |
| PNTSTBYC | pointing standby command complement | logical |
| PNTSTST | pointing state string | string |
| POCANCEL | pointing origin cancel | logical |
| PONAME | pointing origin name | string |
| PONAME1 | pointing origin name 1 | string |
| PONAME2 | pointing origin name 2 | string |
| PONAME3 | pointing origin name 3 | string |
| PONAME4 | pointing origin name 4 | string |
| PONAME5 | pointing origin name 5 | string |
| PONAME6 | pointing origin name 6 | string |
| PONAME7 | pointing origin name 7 | string |
| PONAME8 | pointing origin name 8 | string |
| PONAME9 | pointing origin name 9 | string |
| POOFF | pointing origin offset | logical |
| POPRESET | pointing origin preset | logical |
| PORESET | pointing origin reset | logical |
| POSELECT | pointing origin select | logical |
| POSTAT | pointing origin status | mask |
| POSTAT1 | pointing origin status 1 | mask |
| POSTAT2 | pointing origin status 2 | mask |
| POSTAT3 | pointing origin status 3 | mask |
| POSTAT4 | pointing origin status 4 | mask |
| POSTAT5 | pointing origin status 5 | mask |
| POSTAT6 | pointing origin status 6 | mask |
| POSTAT7 | pointing origin status 7 | mask |
| POSTAT8 | pointing origin status 8 | mask |
| POSTAT9 | pointing origin status 9 | mask |
| POTOTAL | pointing origin total | mask |
| POXBASE | pointing origin x base | double number |
| POXOFF | pointing origin x offset | double number |
| POXPOS | pointing origin xposition | double number |
| POXPOS1 | pointing origin xposition 1 | double number |
| POXPOS2 | pointing origin xposition 2 | double number |
| POXPOS3 | pointing origin xposition 3 | double number |
| POXPOS4 | pointing origin xposition 4 | double number |
| POXPOS5 | pointing origin xposition 5 | double number |
| POXPOS6 | pointing origin xposition 6 | double number |
| POXPOS7 | pointing origin xposition 7 | double number |
| POXPOS8 | pointing origin xposition 8 | double number |
| POXPOS9 | pointing origin xposition 9 | double number |
| POYBASE | pointing origin y base | double number |
| POYOFF | pointing origin y offset | double number |
| POYPOS | pointing origin yposition | double number |
| POYPOS1 | pointing origin yposition 1 | double number |
| POYPOS2 | pointing origin yposition 2 | double number |
| POYPOS3 | pointing origin yposition 3 | double number |
| POYPOS4 | pointing origin yposition 4 | double number |
| POYPOS5 | pointing origin yposition 5 | double number |
| POYPOS6 | pointing origin yposition 6 | double number |
| POYPOS7 | pointing origin yposition 7 | double number |
| POYPOS8 | pointing origin yposition 8 | double number |
| POYPOS9 | pointing origin yposition 9 | double number |
| PRESERVE | preserve pointing | logical |
| PRESROT | preserve rotator physical position | enum |
| PRIMTEMP | acs primary mirror temp | double number |
| PRMAZ | azimuth prm offset | double number |
| PRMEL | elevation | double number |
| RA | telescope right ascension | double number |
| RABASE | telescope right ascension base | double number |
| RAOFF | right ascension offset | double number |
| REL2BASE | relative to base | enum |
| REL2CURR | relative to current | enum |
| RET2OBJ | pointing return to object command | logical |
| RET2OBJC | pointing return to object command complement | logical |
| RET2OBJE | pointing return to object command error string | string |
| RET2OBJS | pointing return to object command error status | integer number |
| ROTBASE | rotator base angle | double number |
| ROTCALAN | rotator calibration angle | double number |
| ROTCASID | cassegrain rotator module id | string |
| ROTCCWLM | rotator ccw limit | double number |
| ROTCWLM | rotator cw limit | double number |
| ROTDEST | rotator user destination | double number |
| ROTDETS1 | rotator destination timestamp1 ut1 slow | double number |
| ROTDETS2 | rotator destination timestamp2 ut1 slow | double number |
| ROTERCNT | rotator error count | integer number |
| ROTERRS | rotator error string | string |
| ROTERVL | rotator error status | integer number |
| ROTFWDID | forward cassegrain rotator module id | string |
| ROTHALT | rotator halt command | logical |
| ROTHALTC | rotator halt command complement | logical |
| ROTHERE | rotator here | logical |
| ROTINIB | rotator initialization command blocking | logical |
| ROTINIT | rotator initialization command | logical |
| ROTINITC | rotator initialization command complement | logical |
| ROTLBCID | left bent cass rotator module id | string |
| ROTMODE | rotator tracking mode | enumm |
| ROTNEED | rotator needed | logical |
| ROTNEWS | rotator new destination slow | integer number |
| ROTOFF | rotator offset | double number |
| ROTPDEST | rotator physical destination | double number |
| ROTPDSTS | rotator physical destination slow | double number |
| ROTPOSN | rotator user position | double number |
| ROTPOTS1 | rotator position timestamp1 ut1 slow | double number |
| ROTPOTS2 | rotator position timestamp2 ut1 slow | double number |
| ROTPPOSN | rotator physical position | double number |
| ROTRBCID | right bent cass rotator module id | string |
| ROTREFAN | rotator reference angle | double number |
| ROTSEL | rotator select | enum |
| ROTSRVER | rotator servo error | double number |
| ROTSTAT | rotator state | enumm |
| ROTSTBY | rotator standby command | logical |
| ROTSTBYC | rotator standby command complement | logical |
| ROTSTST | rotator state string | string |
| ROTZERO | rotator zero angle | double number |
| SCALED | scaled offset | logical |
| SECACTU1 | secondary actuator 1 | double number |
| SECACTU2 | secondary actuator 2 | double number |
| SECACTU3 | secondary actuator 3 | double number |
| SECCALIB | secondary calib comp | logical |
| SECEL | secondary auto el comp | logical |
| SECERRS | secondary error string | string |
| SECERVL | secondary mirror error status | integer number |
| SECFOCOF | telescope focus raw offset | double number |
| SECFOCUS | secondary mirror focus raw | double number |
| SECHALT | secondary halt command | logical |
| SECID | secondary module id | string |
| SECINIB | secondary initialization command blocking | logical |
| SECINIT | secondary initialization command | logical |
| SECMOVE | move secondary | logical |
| SECMTEMP | secondary mirror temp | double number |
| SECNEED | secondary needed | logical |
| SECOFFE | secondary el offset | double number |
| SECOFFR | secondary rot offset | double number |
| SECOFFT | secondary temp_offset | double number |
| SECRAW | secondary cmd raw focus | logical |
| SECREQE | move req el comp | logical |
| SECREQR | move req rot comp | logical |
| SECREQT | move req temp comp | logical |
| SECROT | secondary auto rot comp | logical |
| SECROTAM | secondary auto rot comp amplitude | double number |
| SECROTPH | secondary auto rot comp phase | double number |
| SECSCALE | secondary mirror to sky scale | double number |
| SECSTAT | secondary state | enumm |
| SECSTBY | secondary standby command | logical |
| SECSTST | secondary state string | string |
| SECTEMP | secondary auto temp comp | logical |
| SECTHETX | secondary mirror thetax | double number |
| SECTHETY | secondary mirror thetay | double number |
| SECTHXOF | secondary mirror thetax offset | double number |
| SECTHYOF | secondary mirror thetay offset | double number |
| SECXDEM | secondary mirror thetax demand | double number |
| SECYDEM | secondary mirror thetay demand | double number |
| SECZ | secondary mirror focus compensated | double number |
| SECZDEM | secondary mirror focus compensated demand | double number |
| SHTBTMDN | bottom shutter lowering commanded | enum |
| SHTBTMUP | bottom shutter raising commanded | enum |
| SHTCTRLL | shutter control lower | enum |
| SHTCTRLU | shutter control upper | enum |
| SHTPOSL | shutter elevation lower | double number |
| SHTPOSU | shutter elevation upper | double number |
| SHTPOWER | shutter drive power control command | string |
| SHTSTSL | shutter status lower | string |
| SHTSTSU | shutter status upper | string |
| SHTTOPDN | top shutter lowering commanded | enum |
| SHTTOPUP | top shutter raising commanded | enum |
| SIMULATE | simulating dcs | logical |
| SLEWONLY | slew only total time | double number |
| SLEWTIME | total slew time | double number |
| ST | local apparent sidereal time | double number |
| STRKERR | servo tracking error sky | double number |
| TARGAZ | target azimuth | double number |
| TARGDCJ2 | target declination j2000 | double number |
| TARGDEC | target declination | double number |
| TARGEL | target elevation | double number |
| TARGEPOC | target epoch | double number |
| TARGEQUI | target equinox | double number |
| TARGFRAM | target frame | enumm |
| TARGNAME | target name | string |
| TARGPLAX | target parallax | double number |
| TARGPMDC | target proper motion dec | double number |
| TARGPMRA | target proper motion ra | double number |
| TARGRA | target right ascension | double number |
| TARGRADV | target radial velocity | double number |
| TARGRAJ2 | target right ascension j2000 | double number |
| TARGWAVE | target wavelength | double number |
| TDCBOOT | tdc cage reboot | logical |
| TDCCPU | tdc cpu usage | double number |
| TDCUP | tdc cage up status | logical |
| TDCVERS | tdc cage software version | string |
| TELCCWLM | telescope ccw limit | double number |
| TELCWLM | telescope cw limit | double number |
| TELESCOP | telescope name | string |
| TELFOCOF | telescope focus compensated offset | double number |
| TELFOCUS | telescope focus compensated | double number |
| TELGUARD | telescope guard band | double number |
| TELLOLM | telescope lower el limit | double number |
| TELSHORT | tel shortest path | logical |
| TELUPLM | telescope upper el limit | double number |
| TERTDEST | tertiary destination | enum |
| TERTERRS | tertiary error string | string |
| TERTERVL | tertiary error status | integer number |
| TERTHALT | tertiary halt command | logical |
| TERTINIB | tertiary initialization command blocking | logical |
| TERTINIT | tertiary initialization command | logical |
| TERTMOVE | move tertiary | logical |
| TERTNEED | tertiary needed | logical |
| TERTPOSN | tertiary position | enum |
| TERTSTAT | tertiary state | enumm |
| TERTSTBY | tertiary standby command | logical |
| TERTSTST | tertiary state string | string |
| TPESTEMP | top end socket temp | double number |
| TRACKING | telescope servos tracking | logical |
| TRFIELD | tracking field size | double number |
| TRHYST | tracking hysteresis | double number |
| TRTHRESH | tracking threshold | double number |
| TUBEFLEX | tube flexure | double number |
| TUBETEMP | tube temperature | double number |
| TVANGL | porg to tv angle | double number |
| TVANGL0 | porg to tv angle 0 | double number |
| TVANGL1 | porg to tv angle 1 | double number |
| TVANGL2 | porg to tv angle 2 | double number |
| TVFLIP | porg to tv y flip | logical |
| TVFLIP0 | porg to tv y flip 0 | logical |
| TVFLIP1 | porg to tv y flip 1 | logical |
| TVFLIP2 | porg to tv y flip 2 | logical |
| TVXOFF | tv x offset | double number |
| TVYOFF | tv y offset | double number |
| USEPDPNT | use pdest for pointing | logical |
| UT | coordinated universal time 1 | double number |
| UTC | coordinated universal time | double number |
| VIGNETTE | dome vignette | logical |
| WRAPCTRL | trajectory wrap control | enum |
| XIMOFF | XIM offset | double number |
| YIMOFF | YIM offset | double number |