DEIMOS
User Script Index
Background
The following tables list scripts that can be used to control DEIMOS and/or the telescope. These are useful for two things:
As shortcuts, they can be entered on any
polo
command line to run the instrument in a command-line mode, as is done with NIRC
As building blocks in DEIMOS shell scripts which can perform complex operations.
These commands are always available from any DEIMOS account when logged into the DEIMOS workstation,
polo
.
Contents
CCD - Scripts for CCD control
EXAMPLES - Examples of complex scripts
FCS - Scripts for FCS control
FRAME - Scripts for image names/numbers
IMG - Scripts for taking images
INFO - Scripts for gathering information
MATH - Scripts for doing math
MOT - Scripts for motor control
TEL - Scripts for telescope control
TV - Scripts for guider interaction
DEIMOS Script Library
CCD - Scripts for CCD control
#direct#
-- change CCD readout mode to direct
direct
-- change CCD readout mode to direct
fullframe
-- reset DEIMOS detector to read out entirety of each CCD
oneamp
-- set CCD to single-amp readout mode
spectral
-- change CCD readout mode to spectral, one amp
tint
-- set/show the exposure time on the DEIMOS science detector
twoamps
-- set CCD to dual-amp readout mode
EXAMPLES - Examples of complex scripts
#driftscan#
-- acquire image while drifting target across the slit
align_check
-- check slitmask alignment between spectral exposures
by3
-- acquire images in 3-pos pattern in DETECTOR coords w/ random dither
calib
-- acquire calibration data for DEIMOS slitmask(s)
deimos_flip
-- acquire dithered/rotated image sequence for phot cal
do_focusloop
-- configure DEIMOS and run focusloop
driftscan
-- acquire image while drifting target across the slit
driftscan2
-- acquire image while drifting target across the slit
getsky
--
getsky-align
--
image_user_masks
-- acquire images of DEIMOS user slitmasks
observe_flux_standard
-- acquire spectra for monthly DEIMOS throughput test
post_calib
-- acquire calibration data for DEIMOS slitmask image(s)
FCS - Scripts for FCS control
fcs_change_lamp
-- update FCS reference files to use a new lamp
fcs_logfile
-- return name of the most recently-updated FCS logfile
fcs_tint
-- set or show the FCS integration time
fcsdiff
-- difference fcs the reference fcs image with the current fcs image
fcsmov
-- move a feature to a given position on the DEIMOS FCS image
fcsview
-- view FCS reference image in ds9
fcsview.2008mar11
-- view FCS reference image in ds9
goifcs
-- acquire DEIMOS flexure compensation system image(s)
lastfcsimage
-- return full disk name of the most recent FCS image
nextfcsimage
-- return full disk name of the next FCS image
wffcs
-- wait for FCS to lock on target
wfifcs
-- wait for new DEIMOS FCS image to be written to disk
FRAME - Scripts for image names/numbers
fname
-- Build full DEIMOS file name from frame number
frame
-- set or show the frame number
lastfile
-- return the FRAMENO for the last saved image
lastframe
-- reset frameno to overwrite the last image
lastimage
-- return full disk name of the most recently acquired image
nextfile
-- return one plus the FRAMENO of the last saved image
nextframe
-- reset FRAMENO to the specified value, or 1+last frame
nextimage
-- return full disk name of the next image
IMG - Scripts for taking images
#focusloop#
-- acquire images over a range of internal focus positions
abortex
-- kill any ongoing exposure
bxy5
-- acquire images in 5-pos box pattern in DETECTOR coords
bxy8
-- acquire images in 8-pos box pattern in DETECTOR coords
bxy9
-- acquire images in 9-pos box pattern in DETECTOR coords
focusloop
-- acquire images over a range of internal focus positions
goi
-- acquire DEIMOS image(s)
goibuf
-- take DEIMOS image(s) without saving to disk
goidark
-- acquire dark DEIMOS image(s)
goisleep
-- acquire images with pauses in between
level_check
-- acquire a quick DEIMOS image to check exposure levels
mosaic
-- acquire mosaiced image sequence
telfocloop
-- acquire images over a range of secondary piston positions
INFO - Scripts for gathering information
UTdate
--
apropos
-- parse DEIMOS command help for requested string
barcodes
-- print the barcodes for all loaded slitmasks
consort
-- print sorted list of current configurable elements
datadirs
-- print summary of recent data directories
deeplog
-- generate logsheet data from image headers
dir
-- list FITS images in the current output directory
disks
-- print out a listing of available data disks
help
-- print documentation for a DEIMOS script, or list all scripts
inventory
-- convert between guiname, barcode, and blueprint ID
is_float
-- check whether the argument is floating point number
masknames
-- print the name(s) of currently-loaded slitmasks
newday
-- set up directory, filename prefix, etc.
newdir
-- create a new output directory for DEIMOS images
nightpath
-- return the path of the 'nightly' directory
object
-- show/change the OBJECT name
observer
-- set/show observer name(s)
outdir
-- set/show the current output directory
pause
-- suspend execution until user presses <RETURN>
restore_state
-- restore previously saved INSTRUMENT configuration
save_state
-- store instrument settings for future restoration
script_done
-- notify observer that a script has finished
set_state
-- reconfigure DEIMOS
showkeywords
-- list all DEIMOS keywords
skey
-- list all DEIMOS keywords
tkmessage
-- post a warning message using Tcl/Tk widget
tolower
-- convert argument(s) to lower case
toupper
-- convert argument(s) to upper case
wfi
-- wait for new DEIMOS image to be written to disk
MATH - Scripts for doing math
abs
-- return the absolute value
ampang
-- compute distance + bearing between two locations on DEIMOS image
calc
-- evaluate an arbitrary arithmetic statement using GAWK
grand
-- generate a normal (Gaussian) random value
imarith
-- perform simple image arithmetic
irand
-- generate a uniform random integer value between 0 and 32768
rand
-- generate a uniform random value between 0 and 1
sex2dec
-- convert from sexagesimal to decimal
MOT - Scripts for motor control
cycle_shutter
-- perform an open/close sequence on the DEIMOS CCD shutter
domelamps
-- turn spectral or imaging dome lamps on or off, or show status
filter
-- show or select the DEIMOS filter by name
focus
-- show or set the DEIMOS dewar focus value
focus.new
-- show or set the DEIMOS dewar focus value
gozero
-- set slider 3 or 4 to zeroth order imaging position
gratecal
-- recalibrate the tilt for the current grating
grating
-- show or select the DEIMOS grating and wavelength
lamps
-- turn DEIMOS calibration lamps on/off and show status
rotang
-- set/show physical DEIMOS rotator angle
rotatcal
-- home (calibratre) the DEIMOS rotator
rotatloop
-- step the rotator and pause between moves
skypa
-- set rotator celestial position angle in position angle mode
slider
-- show or select the DEIMOS grating slider position
slitmask
-- show or select the DEIMOS slitmask by name
wavelen
-- set/show the wavelength on the current slider
TEL - Scripts for telescope control
az
-- move the telescope x arcsec in azimuth
azel
-- move the telescope x arcsec in azimuth and y arcsec in elevation
east
-- move the telescope east
el
-- move the telescope x arcsec in elevation
en
-- move the telescope east and north
gcent
-- move an object to the center of the guider pickoff mirror
gmov
-- move an object to a given position on the DEIMOS guider
gotobase
-- move the telescope to return to the base coordinates
gxy
-- move the telescope in GUIDER coordinates
markbase
-- set the base telescope coordinates to the current coordinates
mov
-- move an object to a given position on the DEIMOS detector
mx
-- move telescope along rows in detector coordinate system
mxy
-- move telescope in instrument (detector) coordinates
my
-- move telescope along columns in detector coordinate system
north
-- move the telescope north
pmfm
-- set/show the amount of focus mode in the telescope primary
poname
-- set or show the current pointing origin
px
-- move telescope along the "x" direction in DEIMOS pixel units
pxy
-- move telescope in pixel coordinates of the DEIMOS detector
py
-- move telescope along the "y" direction in DEIMOS pixel units
ref2slit
-- offset star at REF onto slit at (x,y)
south
-- move the telescope south
telfoc
-- set/show the telescope secondary position
west
-- move the telescope west
TV - Scripts for guider interaction
lasttvimage
-- return full disk name of the most recent TV image
tvfilter
-- show or select the DEIMOS guider filter by name
tvfocloop
-- increment TV focus when images are saved
tvfocus
-- show or set the DEIMOS guider focus value
tvpower
-- show or set state of DEIMOS guider power
wftv
-- wait for new TV image
Go to:
DEIMOS Home Page
-
Instruments Home Page
-
Keck Home Page
Last modified: