DEIMOS
Science CCD Controller Powerup Procedure

Background

This document descibes the procedure for turning on power to the DEIMOS science CCD array after controller power has been restored at the chassis.

Procedure

  1. Log into deimosserver using the dmoseng account.
  2. From the command line prompt in an xterm window, type the following command to start a crate session:
    	start_crate s
  3. At the VME prompt, issue the i command and verify that neither the broad_mon nor the dewar_temp tasks are running. They must be stopped if they they are running by issuing the following commands:
    	deimos_dewar_temperature_exit = 1
    	broadcast_monitor_exit = 1
    After executing those commands, issue the i command again and verify that the jobs were properly terminated.
  4. Issue the command
    	< restart
    to invoke the restart script and verify that it completes without error.

Transcript

Below is a transcript of a successful completion of the DEIMOS powerup command, with user input in blue and commentary in red. Please note the following:
First, determine what tasks are running:
-> i

  NAME        ENTRY       TID    PRI   STATUS      PC       SP     ERRNO  DELAY
---------- ------------ -------- --- ---------- -------- -------- ------- -----
tExcTask   excTask       3dfe1b8   0 PEND         185940  3dfe0e0       0     0
tLogTask   logTask       3dfb840   0 PEND         185940  3dfb778       0     0
tShell     shell         3de4788   1 READY        157924  3de4408   30065     0
tRlogind   rlogind       3df3770   2 PEND         153f60  3df33b0       0     0
tTelnetd   telnetd       3df1848   2 PEND         153f60  3df16e8       0     0
tRlogOutTasrlogOutTask   3ffee28   2 READY        153f60  3ffeca0       0     0
tRlogInTaskrlogInTask    3ddea30   2 READY        153e4c  3dde898       0     0
tWdbTask   14c1c4        3de6f38   3 PEND         153f60  3de6da0       0     0
tNetTask   netTask       3df6c38  50 READY        15531c  3df6b70       0     0
tTftpdTask tftpdTask     3deebf0  55 PEND         153f60  3dee428       0     0
ccdClock   ccdClock      3c33ed0  90 DELAY        156ed8  3c33e10       0     1
tPortmapd  portmapd      3df02b8 100 PEND         153f60  3df0148      16     0
MLOG_STDOUTstart_mlog_s  3c69550 100 PEND         185940  3c69250       0     0
cserv      cserv         3c50ca8 100 PEND         153f60  3c50a90       0     0
responder  responder     3b3c518 100 PEND         185940  3b3b400       0     0
broad_mon  broadcast_mo  3b20800 110 DELAY        156ed8  3b20740       0    35
rccd       rccd          3c2a088 150 PEND+T       153f60  3c29ee8  3d0004    14
dewar_temp deimos_dewar  3b1be20 160 DELAY        156ed8  3b1bc78  3d0001     4
value = 0 = 0x0

Next, halt the broad_mon and dewar_temp processes:
-> deimos_dewar_temperature_exit = 1
deimos_dewar_temperature_exit = 0x3d1f608: value = 1 = 0x1
-> broadcast_monitor_exit = 1
broadcast_monitor_exit = 0x3b480e8: value = 1 = 0x1

Verify that those processes are gone:
-> i

  NAME        ENTRY       TID    PRI   STATUS      PC       SP     ERRNO  DELAY
---------- ------------ -------- --- ---------- -------- -------- ------- -----
tExcTask   excTask       3dfe1b8   0 PEND         185940  3dfe0e0       0     0
tLogTask   logTask       3dfb840   0 PEND         185940  3dfb778       0     0
tShell     shell         3de4788   1 READY        157924  3de4408   30065     0
tRlogind   rlogind       3df3770   2 PEND         153f60  3df33b0       0     0
tTelnetd   telnetd       3df1848   2 PEND         153f60  3df16e8       0     0
tRlogOutTasrlogOutTask   3ffee28   2 READY        153f60  3ffeca0       0     0
tRlogInTaskrlogInTask    3ddea30   2 READY        153e4c  3dde898       0     0
tWdbTask   14c1c4        3de6f38   3 PEND         153f60  3de6da0       0     0
tNetTask   netTask       3df6c38  50 READY        15531c  3df6b70       0     0
tTftpdTask tftpdTask     3deebf0  55 PEND         153f60  3dee428       0     0
ccdClock   ccdClock      3c33ed0  90 READY        156ed8  3c33e10       0     0
tPortmapd  portmapd      3df02b8 100 PEND         153f60  3df0148      16     0
MLOG_STDOUTstart_mlog_s  3c69550 100 PEND         185940  3c69250       0     0
cserv      cserv         3c50ca8 100 PEND         153f60  3c50a90       0     0
responder  responder     3b3c518 100 PEND         185940  3b3b400       0     0
rccd       rccd          3c2a088 150 PEND+T       153f60  3c29ee8  3d0004    39
value = 0 = 0x0

Launch the restart script:
-> < restart
startup("/vx/deivme/dsp",0)
Sending STP command to TIMING board
Sending LOR command to TIMING board
UTB application 0 test location= 10
UTB digital output= bf80
Analog switches in dewar electronics commanded open
Analog switches in dewar electronics indicate open
Sending hardware reset to TIMING board
msg size = 2 words.  reply size = 2 words
msg = 0X102 0X54544852
reply = 0X10002 0X444f4e
Sending STP command to TIMING board
Will verify vmeinf eprom against /vx/deivme/dsp/vmeinf/vme.s
VMEINF board verification status= 0, should be 0
Will verify timing eprom against /vx/deivme/dsp/timing/timing.s
TIMING board verification status= 0, should be 0
Will verify utility eprom against /vx/deivme/dsp/utility/util.s
Expecting 1 verification error: at 800081
verify error: at address 800081  expected: 000004  got: 052d79
EOF
UTILITY board verification status= 1, should be 1
EEPROMs verified correctly. Proceeding with power-up
+5v readback raw ADC reading = 3424 volts= 5.031704 prior to enables
+15v readback raw ADC reading = 3490 voltage = 16.015638 prior to enable
-15v readback raw ADC reading = 622 voltage = -16.035444 prior to enable
+30v readback raw ADC reading = 2049 volts = 0.028058 prior to enable
UTB digital output= bf80
+/-15v power enabled
+5v readback raw ADC reading = 3425 volts= 5.035361 after 15v enable
+15v readback raw ADC reading = 3494 voltage = 16.060064 after 15v enable
-15v readback raw ADC reading = 619 voltage = -16.069180 after 15v enable
+30v readback raw ADC reading = 2049 volts = 0.028058 after 15v enable
UTB digital output= be80
+30v power enabled
+5v readback raw ADC reading = 3425 volts= 5.035361 prior after enables
+15v readback raw ADC reading = 3495 voltage = 16.071171 after enables
-15v readback raw ADC reading = 619 voltage = -16.069180 after enables
+30v readback raw ADC reading = 3283 volts = 34.651104 after enables
Analog switches in dewar electronics commanded open
Analog switches in dewar electronics indicate open
Bias and clock voltages have been set, but not yet sent to CCD
Bias voltages for CCD 1
CCD 1 bias  0 ADC 3362 ( d22) MUX  1.919 Volts 19.191  Vdd-1
CCD 1 bias  1 ADC 3361 ( d21) MUX  1.918 Volts 19.176  Vdd-2
CCD 1 bias  2 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-A
CCD 1 bias  3 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-B
CCD 1 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 1 bias  5 ADC 3387 ( d3b) MUX  1.956 Volts  3.912  Spare-2
CCD 1 bias  6 ADC 2725 ( aa5) MUX  0.988 Volts  9.880  Guard ring
CCD 1 bias  7 ADC 2050 ( 802) MUX  0.001 Volts  0.001  Substrate
CCD 1 bias  8 ADC 3387 ( d3b) MUX  1.956 Volts  3.912  Spare-1
CCD 1 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 1 bias 10 ADC 3390 ( d3e) MUX  1.961 Volts  3.921  Spare-3
CCD 1 bias 11 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Bi-polar Spare
CCD 1 bias 12 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 1 bias 13 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 1 bias 14 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 1 bias 15 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
Bias voltages for CCD 2
CCD 2 bias  0 ADC 3398 ( d46) MUX  1.972 Volts 19.717  Vdd-1
CCD 2 bias  1 ADC 3331 ( d03) MUX  1.874 Volts 18.738  Vdd-2
CCD 2 bias  2 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-A
CCD 2 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 2 bias  4 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-A
CCD 2 bias  5 ADC 3388 ( d3c) MUX  1.958 Volts  3.915  Spare-2
CCD 2 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 2 bias  7 ADC 2052 ( 804) MUX  0.004 Volts  0.004  Substrate
CCD 2 bias  8 ADC 3390 ( d3e) MUX  1.961 Volts  3.921  Spare-1
CCD 2 bias  9 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-B
CCD 2 bias 10 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-3
CCD 2 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 2 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 2 bias 13 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 2 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 2 bias 15 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
Bias voltages for CCD 3
CCD 3 bias  0 ADC 3324 ( cfc) MUX  1.864 Volts 18.635  Vdd-1
CCD 3 bias  1 ADC 3323 ( cfb) MUX  1.862 Volts 18.621  Vdd-2
CCD 3 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 3 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 3 bias  4 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-A
CCD 3 bias  5 ADC 3393 ( d41) MUX  1.965 Volts  3.930  Spare-2
CCD 3 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 3 bias  7 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Substrate
CCD 3 bias  8 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-1
CCD 3 bias  9 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-B
CCD 3 bias 10 ADC 3392 ( d40) MUX  1.963 Volts  3.927  Spare-3
CCD 3 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 3 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 3 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 3 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 3 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 4
CCD 4 bias  0 ADC 3362 ( d22) MUX  1.919 Volts 19.191  Vdd-1
CCD 4 bias  1 ADC 3362 ( d22) MUX  1.919 Volts 19.191  Vdd-2
CCD 4 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 4 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 4 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 4 bias  5 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-2
CCD 4 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 4 bias  7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003  Substrate
CCD 4 bias  8 ADC 3394 ( d42) MUX  1.966 Volts  3.933  Spare-1
CCD 4 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 4 bias 10 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-3
CCD 4 bias 11 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Bi-polar Spare
CCD 4 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 4 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 4 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 4 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 5
CCD 5 bias  0 ADC 3430 ( d66) MUX  2.019 Volts 20.185  Vdd-1
CCD 5 bias  1 ADC 3395 ( d43) MUX  1.967 Volts 19.673  Vdd-2
CCD 5 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 5 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 5 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 5 bias  5 ADC 3388 ( d3c) MUX  1.958 Volts  3.915  Spare-2
CCD 5 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 5 bias  7 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Substrate
CCD 5 bias  8 ADC 3394 ( d42) MUX  1.966 Volts  3.933  Spare-1
CCD 5 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 5 bias 10 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-3
CCD 5 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 5 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 5 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 5 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 5 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 6
CCD 6 bias  0 ADC 3396 ( d44) MUX  1.969 Volts 19.688  Vdd-1
CCD 6 bias  1 ADC 3326 ( cfe) MUX  1.866 Volts 18.665  Vdd-2
CCD 6 bias  2 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-A
CCD 6 bias  3 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-B
CCD 6 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 6 bias  5 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-2
CCD 6 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 6 bias  7 ADC 2048 ( 800) MUX -0.001 Volts -0.001  Substrate
CCD 6 bias  8 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-1
CCD 6 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 6 bias 10 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-3
CCD 6 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 6 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 6 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 6 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 6 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 7
CCD 7 bias  0 ADC 3326 ( cfe) MUX  1.866 Volts 18.665  Vdd-1
CCD 7 bias  1 ADC 3393 ( d41) MUX  1.964 Volts 19.644  Vdd-2
CCD 7 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 7 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 7 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 7 bias  5 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-2
CCD 7 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 7 bias  7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003  Substrate
CCD 7 bias  8 ADC 3392 ( d40) MUX  1.963 Volts  3.927  Spare-1
CCD 7 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 7 bias 10 ADC 3390 ( d3e) MUX  1.961 Volts  3.921  Spare-3
CCD 7 bias 11 ADC 3388 ( d3c) MUX  1.958 Volts 19.576  Bi-polar Spare
CCD 7 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 7 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 7 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 7 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 8
CCD 8 bias  0 ADC 3325 ( cfd) MUX  1.865 Volts 18.650  Vdd-1
CCD 8 bias  1 ADC 3381 ( d35) MUX  1.947 Volts 19.469  Vdd-2
CCD 8 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 8 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 8 bias  4 ADC 2051 ( 803) MUX  0.002 Volts  0.004  OG-A
CCD 8 bias  5 ADC 3392 ( d40) MUX  1.963 Volts  3.927  Spare-2
CCD 8 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 8 bias  7 ADC 2058 ( 80a) MUX  0.013 Volts  0.013  Substrate
CCD 8 bias  8 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-1
CCD 8 bias  9 ADC 2051 ( 803) MUX  0.002 Volts  0.004  OG-B
CCD 8 bias 10 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-3
CCD 8 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 8 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 8 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 8 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 8 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Open bias voltages are all within tolerance
Low-rail clock voltages for clock gen 1
CLKGEN 1 clock  0 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock  1 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock  3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 1 clock  4 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  5 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  6 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock  7 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  8 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 1 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 1 clock 11 ADC 2049 ( 801) MUX  0.001 Volts  0.015
CLKGEN 1 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 1 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 1 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 1 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 1
CLKGEN 1 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 1 clock  1 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 1 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 1 clock  3 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 1 clock  4 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  5 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  6 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  7 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  8 ADC 2459 ( 99b) MUX  0.602 Volts  6.018
CLKGEN 1 clock  9 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 1 clock 10 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 1 clock 11 ADC 2595 ( a23) MUX  0.801 Volts  8.009
CLKGEN 1 clock 12 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 1 clock 13 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 1 clock 14 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 1 clock 15 ADC 2391 ( 957) MUX  0.502 Volts  5.022
CLKGEN 1 clock 16 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 17 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 18 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 19 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 20 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 21 ADC 2391 ( 957) MUX  0.502 Volts  5.022
CLKGEN 1 clock 22 ADC 2594 ( a22) MUX  0.799 Volts  7.994
CLKGEN 1 clock 23 ADC 2594 ( a22) MUX  0.799 Volts  7.994
Low-rail clock voltages for clock gen 2
CLKGEN 2 clock  0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 2 clock  1 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock  3 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 2 clock  4 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  5 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  6 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  7 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 2 clock  8 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  9 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 2 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 2 clock 11 ADC 2049 ( 801) MUX  0.001 Volts  0.015
CLKGEN 2 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 2 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 18 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 2 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 2 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 2 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 2
CLKGEN 2 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 2 clock  1 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 2 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 2 clock  3 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 2 clock  4 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  5 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  6 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  7 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  8 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  9 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 2 clock 10 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 2 clock 11 ADC 2594 ( a22) MUX  0.799 Volts  7.994
CLKGEN 2 clock 12 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 2 clock 13 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 2 clock 14 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 2 clock 15 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 2 clock 16 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 17 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 18 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 19 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 20 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 21 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 2 clock 22 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 2 clock 23 ADC 2595 ( a23) MUX  0.801 Volts  8.009
Low-rail clock voltages for clock gen 3
CLKGEN 3 clock  0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 3 clock  1 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 3 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 3 clock  3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock  4 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  5 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  6 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  7 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  8 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 3 clock 11 ADC 2049 ( 801) MUX  0.001 Volts  0.015
CLKGEN 3 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 3 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 3 clock 14 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 3 clock 15 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock 16 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 3 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 3 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 3 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 3 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 3
CLKGEN 3 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 3 clock  1 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock  3 ADC 2389 ( 955) MUX  0.499 Volts  4.993
CLKGEN 3 clock  4 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  5 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  6 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  7 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  8 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  9 ADC 2389 ( 955) MUX  0.499 Volts  4.993
CLKGEN 3 clock 10 ADC 2592 ( a20) MUX  0.796 Volts  7.965
CLKGEN 3 clock 11 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 3 clock 12 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock 13 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock 14 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock 15 ADC 2389 ( 955) MUX  0.499 Volts  4.993
CLKGEN 3 clock 16 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 17 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 18 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 19 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 20 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 21 ADC 2389 ( 955) MUX  0.499 Volts  4.993
CLKGEN 3 clock 22 ADC 2592 ( a20) MUX  0.796 Volts  7.965
CLKGEN 3 clock 23 ADC 2593 ( a21) MUX  0.798 Volts  7.980
Low-rail clock voltages for clock gen 4
CLKGEN 4 clock  0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 4 clock  1 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock  3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 4 clock  4 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock  5 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 4 clock  6 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock  7 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock  8 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock  9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 4 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 4 clock 11 ADC 2049 ( 801) MUX  0.001 Volts  0.015
CLKGEN 4 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 4 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 4 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 19 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 4 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 21 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 4 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 4 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 4
CLKGEN 4 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 4 clock  1 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 4 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 4 clock  3 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock  4 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  5 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  6 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 4 clock  7 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  8 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 4 clock  9 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock 10 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 4 clock 11 ADC 2594 ( a22) MUX  0.799 Volts  7.994
CLKGEN 4 clock 12 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 4 clock 13 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 4 clock 14 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 4 clock 15 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock 16 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 17 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 18 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 19 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 20 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 21 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock 22 ADC 2593 ( a21) MUX  0.798 Volts  7.980
Readccd task is still alive
CLKGEN 4 clock 23 ADC 2594 ( a22) MUX  0.799 Volts  7.994
Open clock voltages are all within tolerance
Switch states set to select clock low rails
VDD and RD bias voltages have all been set to minimum voltage
Analog switches commanded closed.
Analog switches in dewar electronics indicate closed
+5v readback raw ADC reading = 3425 volts= 5.035361 after closure
+15v readback raw ADC reading = 3494 voltage = 16.060064 after closure
-15v readback raw ADC reading = 618 voltage = -16.080425 after closure
+30v readback raw ADC reading = 3283 volts = 34.651104 after closure
About to pulse all RG clocks with a +2 volt pulse
About to drop all RG clocks back to 0 volts
About to command VDD and RD back to nominal values
VDD, RD, and RG have been commanded to nominal voltage
CCD is now powered up.
Bias voltages for CCD 1
CCD 1 bias  0 ADC 3351 ( d17) MUX  1.903 Volts 19.030  Vdd-1
CCD 1 bias  1 ADC 3351 ( d17) MUX  1.903 Volts 19.030  Vdd-2
CCD 1 bias  2 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-A
CCD 1 bias  3 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-B
CCD 1 bias  4 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-A
CCD 1 bias  5 ADC 3387 ( d3b) MUX  1.956 Volts  3.912  Spare-2
CCD 1 bias  6 ADC 2725 ( aa5) MUX  0.988 Volts  9.880  Guard ring
CCD 1 bias  7 ADC 2050 ( 802) MUX  0.001 Volts  0.001  Substrate
CCD 1 bias  8 ADC 3387 ( d3b) MUX  1.956 Volts  3.912  Spare-1
CCD 1 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 1 bias 10 ADC 3390 ( d3e) MUX  1.961 Volts  3.921  Spare-3
CCD 1 bias 11 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Bi-polar Spare
CCD 1 bias 12 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 1 bias 13 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 1 bias 14 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 1 bias 15 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
Bias voltages for CCD 2
CCD 2 bias  0 ADC 3387 ( d3b) MUX  1.956 Volts 19.556  Vdd-1
CCD 2 bias  1 ADC 3321 ( cf9) MUX  1.859 Volts 18.592  Vdd-2
CCD 2 bias  2 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-A
CCD 2 bias  3 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-B
CCD 2 bias  4 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-A
CCD 2 bias  5 ADC 3388 ( d3c) MUX  1.958 Volts  3.915  Spare-2
CCD 2 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 2 bias  7 ADC 2052 ( 804) MUX  0.004 Volts  0.004  Substrate
CCD 2 bias  8 ADC 3390 ( d3e) MUX  1.961 Volts  3.921  Spare-1
CCD 2 bias  9 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-B
CCD 2 bias 10 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-3
CCD 2 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 2 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 2 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 2 bias 14 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 2 bias 15 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
Bias voltages for CCD 3
CCD 3 bias  0 ADC 3314 ( cf2) MUX  1.849 Volts 18.489  Vdd-1
CCD 3 bias  1 ADC 3313 ( cf1) MUX  1.847 Volts 18.475  Vdd-2
CCD 3 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 3 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 3 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 3 bias  5 ADC 3393 ( d41) MUX  1.965 Volts  3.930  Spare-2
CCD 3 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 3 bias  7 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Substrate
CCD 3 bias  8 ADC 3390 ( d3e) MUX  1.961 Volts  3.921  Spare-1
CCD 3 bias  9 ADC 2050 ( 802) MUX  0.000 Volts  0.001  OG-B
CCD 3 bias 10 ADC 3392 ( d40) MUX  1.963 Volts  3.927  Spare-3
CCD 3 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 3 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 3 bias 13 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Ground
CCD 3 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 3 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 4
CCD 4 bias  0 ADC 3351 ( d17) MUX  1.903 Volts 19.030  Vdd-1
CCD 4 bias  1 ADC 3352 ( d18) MUX  1.904 Volts 19.045  Vdd-2
CCD 4 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 4 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 4 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 4 bias  5 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-2
CCD 4 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 4 bias  7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003  Substrate
CCD 4 bias  8 ADC 3394 ( d42) MUX  1.966 Volts  3.933  Spare-1
CCD 4 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 4 bias 10 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-3
CCD 4 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 4 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 4 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 4 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 4 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 5
CCD 5 bias  0 ADC 3426 ( d62) MUX  2.013 Volts 20.127  Vdd-1
Invalid voltage 20.127 for Vdd-1 on CCD 5; should be 19.995
CCD 5 bias  1 ADC 3385 ( d39) MUX  1.953 Volts 19.527  Vdd-2
CCD 5 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 5 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 5 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 5 bias  5 ADC 3388 ( d3c) MUX  1.958 Volts  3.915  Spare-2
CCD 5 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 5 bias  7 ADC 2049 ( 801) MUX  0.000 Volts  0.000  Substrate
CCD 5 bias  8 ADC 3394 ( d42) MUX  1.966 Volts  3.933  Spare-1
CCD 5 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 5 bias 10 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-3
CCD 5 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 5 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 5 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 5 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 5 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 6
CCD 6 bias  0 ADC 3385 ( d39) MUX  1.953 Volts 19.527  Vdd-1
CCD 6 bias  1 ADC 3316 ( cf4) MUX  1.852 Volts 18.518  Vdd-2
CCD 6 bias  2 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-A
CCD 6 bias  3 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-B
CCD 6 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 6 bias  5 ADC 3388 ( d3c) MUX  1.958 Volts  3.915  Spare-2
CCD 6 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 6 bias  7 ADC 2048 ( 800) MUX -0.001 Volts -0.001  Substrate
CCD 6 bias  8 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-1
CCD 6 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 6 bias 10 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-3
CCD 6 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 6 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 6 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 6 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 6 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 7
CCD 7 bias  0 ADC 3316 ( cf4) MUX  1.852 Volts 18.518  Vdd-1
CCD 7 bias  1 ADC 3382 ( d36) MUX  1.948 Volts 19.483  Vdd-2
CCD 7 bias  2 ADC 2912 ( b60) MUX  1.260 Volts 12.603  RD-A
CCD 7 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 7 bias  4 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-A
CCD 7 bias  5 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-2
CCD 7 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 7 bias  7 ADC 2047 ( 7ff) MUX -0.003 Volts -0.003  Substrate
CCD 7 bias  8 ADC 3392 ( d40) MUX  1.963 Volts  3.927  Spare-1
CCD 7 bias  9 ADC 2049 ( 801) MUX -0.001 Volts -0.002  OG-B
CCD 7 bias 10 ADC 3390 ( d3e) MUX  1.961 Volts  3.921  Spare-3
CCD 7 bias 11 ADC 3388 ( d3c) MUX  1.958 Volts 19.576  Bi-polar Spare
CCD 7 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 7 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 7 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 7 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
Bias voltages for CCD 8
CCD 8 bias  0 ADC 3316 ( cf4) MUX  1.852 Volts 18.518  Vdd-1
CCD 8 bias  1 ADC 3369 ( d29) MUX  1.929 Volts 19.293  Vdd-2
CCD 8 bias  2 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-A
CCD 8 bias  3 ADC 2913 ( b61) MUX  1.262 Volts 12.617  RD-B
CCD 8 bias  4 ADC 2051 ( 803) MUX  0.002 Volts  0.004  OG-A
CCD 8 bias  5 ADC 3392 ( d40) MUX  1.963 Volts  3.927  Spare-2
CCD 8 bias  6 ADC 2726 ( aa6) MUX  0.989 Volts  9.894  Guard ring
CCD 8 bias  7 ADC 2057 ( 809) MUX  0.012 Volts  0.012  Substrate
CCD 8 bias  8 ADC 3389 ( d3d) MUX  1.959 Volts  3.918  Spare-1
CCD 8 bias  9 ADC 2051 ( 803) MUX  0.002 Volts  0.004  OG-B
CCD 8 bias 10 ADC 3391 ( d3f) MUX  1.962 Volts  3.924  Spare-3
CCD 8 bias 11 ADC 2050 ( 802) MUX  0.001 Volts  0.015  Bi-polar Spare
CCD 8 bias 12 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 8 bias 13 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 8 bias 14 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
CCD 8 bias 15 ADC 2050 ( 802) MUX  0.001 Volts  0.000  Ground
1 closed bias voltages were not within tolerance
Check to see if something is loading down the affected bias voltages
Low-rail clock voltages for clock gen 1
CLKGEN 1 clock  0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 1 clock  1 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock  3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 1 clock  4 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  5 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  6 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock  7 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  8 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock  9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 1 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 1 clock 11 ADC 2050 ( 802) MUX  0.003 Volts  0.029
CLKGEN 1 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 1 clock 14 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 1 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 1 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 1 clock 19 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock 20 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 1 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 1 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 1 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 1
CLKGEN 1 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 1 clock  1 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 1 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 1 clock  3 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 1 clock  4 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  5 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  6 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  7 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock  8 ADC 2459 ( 99b) MUX  0.602 Volts  6.018
CLKGEN 1 clock  9 ADC 2391 ( 957) MUX  0.502 Volts  5.022
CLKGEN 1 clock 10 ADC 2594 ( a22) MUX  0.799 Volts  7.994
CLKGEN 1 clock 11 ADC 2595 ( a23) MUX  0.801 Volts  8.009
CLKGEN 1 clock 12 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 1 clock 13 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 1 clock 14 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 1 clock 15 ADC 2391 ( 957) MUX  0.502 Volts  5.022
CLKGEN 1 clock 16 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 17 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 18 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 19 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 20 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 1 clock 21 ADC 2391 ( 957) MUX  0.502 Volts  5.022
CLKGEN 1 clock 22 ADC 2594 ( a22) MUX  0.799 Volts  7.994
CLKGEN 1 clock 23 ADC 2594 ( a22) MUX  0.799 Volts  7.994
Low-rail clock voltages for clock gen 2
CLKGEN 2 clock  0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 2 clock  1 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock  3 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 2 clock  4 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  5 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  6 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  7 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 2 clock  8 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock  9 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 2 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 2 clock 11 ADC 2049 ( 801) MUX  0.001 Volts  0.015
CLKGEN 2 clock 12 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 2 clock 15 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 2 clock 16 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 18 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 2 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 2 clock 21 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 2 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 2 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 2
CLKGEN 2 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 2 clock  1 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 2 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 2 clock  3 ADC 2391 ( 957) MUX  0.502 Volts  5.022
CLKGEN 2 clock  4 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  5 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  6 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  7 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  8 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock  9 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 2 clock 10 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 2 clock 11 ADC 2595 ( a23) MUX  0.801 Volts  8.009
CLKGEN 2 clock 12 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 2 clock 13 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 2 clock 14 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 2 clock 15 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 2 clock 16 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 17 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 18 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 19 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 20 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 2 clock 21 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 2 clock 22 ADC 2594 ( a22) MUX  0.799 Volts  7.994
CLKGEN 2 clock 23 ADC 2595 ( a23) MUX  0.801 Volts  8.009
Low-rail clock voltages for clock gen 3
CLKGEN 3 clock  0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 3 clock  1 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 3 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 3 clock  3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock  4 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 3 clock  5 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  6 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  7 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  8 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock  9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 3 clock 11 ADC 2049 ( 801) MUX  0.001 Volts  0.015
CLKGEN 3 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 3 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 3 clock 14 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 3 clock 15 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock 16 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock 17 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock 18 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock 19 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 3 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 3 clock 21 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 3 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 3 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 3
CLKGEN 3 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 3 clock  1 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock  3 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 3 clock  4 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  5 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  6 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  7 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  8 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock  9 ADC 2389 ( 955) MUX  0.499 Volts  4.993
CLKGEN 3 clock 10 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 3 clock 11 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 3 clock 12 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 3 clock 13 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock 14 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 3 clock 15 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 3 clock 16 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 17 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 18 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 19 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 20 ADC 2457 ( 999) MUX  0.599 Volts  5.988
CLKGEN 3 clock 21 ADC 2389 ( 955) MUX  0.499 Volts  4.993
CLKGEN 3 clock 22 ADC 2592 ( a20) MUX  0.796 Volts  7.965
CLKGEN 3 clock 23 ADC 2593 ( a21) MUX  0.798 Volts  7.980
Low-rail clock voltages for clock gen 4
CLKGEN 4 clock  0 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 4 clock  1 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock  2 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock  3 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 4 clock  4 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock  5 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 4 clock  6 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock  7 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 4 clock  8 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock  9 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 4 clock 10 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 4 clock 11 ADC 2049 ( 801) MUX  0.001 Volts  0.015
CLKGEN 4 clock 12 ADC 1642 ( 66a) MUX -0.594 Volts -5.944
CLKGEN 4 clock 13 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock 14 ADC 1641 ( 669) MUX -0.596 Volts -5.959
CLKGEN 4 clock 15 ADC 1709 ( 6ad) MUX -0.496 Volts -4.963
CLKGEN 4 clock 16 ADC 1845 ( 735) MUX -0.297 Volts -2.972
CLKGEN 4 clock 17 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 18 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 19 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 20 ADC 1844 ( 734) MUX -0.299 Volts -2.987
CLKGEN 4 clock 21 ADC 1708 ( 6ac) MUX -0.498 Volts -4.978
CLKGEN 4 clock 22 ADC 2048 ( 800) MUX  0.000 Volts  0.000
CLKGEN 4 clock 23 ADC 2049 ( 801) MUX  0.001 Volts  0.015
High-rail clock voltages for clock gen 4
CLKGEN 4 clock  0 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 4 clock  1 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 4 clock  2 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 4 clock  3 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock  4 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  5 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  6 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  7 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  8 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock  9 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock 10 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 4 clock 11 ADC 2594 ( a22) MUX  0.799 Volts  7.994
CLKGEN 4 clock 12 ADC 2186 ( 88a) MUX  0.202 Volts  2.020
CLKGEN 4 clock 13 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 4 clock 14 ADC 2185 ( 889) MUX  0.201 Volts  2.006
CLKGEN 4 clock 15 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock 16 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 17 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 18 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 19 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 20 ADC 2458 ( 99a) MUX  0.600 Volts  6.003
CLKGEN 4 clock 21 ADC 2390 ( 956) MUX  0.501 Volts  5.007
CLKGEN 4 clock 22 ADC 2593 ( a21) MUX  0.798 Volts  7.980
CLKGEN 4 clock 23 ADC 2595 ( a23) MUX  0.801 Volts  8.009
Closed clock voltages are all within tolerance
Now commanding shutter closed
+5v readback raw ADC reading = 3425 volts= 5.035361 prior to clocking
+15v readback raw ADC reading = 3495 voltage = 16.071171 prior to clocking
-15v readback raw ADC reading = 619 voltage = -16.069180 prior to clocking
+30v readback raw ADC reading = 3281 volts = 34.594990 prior to clocking
Sending IDL command to TIMING board
CCD clocks are now running in idling mode
value = 0 = 0x0

Verify that the restart script completed without error.

-> logout
Connection closed.
      


Go to: DEIMOS Home Page - Instruments Home Page - Keck Home Page

Last modified: Fri Oct 2 11:38:48 HST 2009